Journal of Global Infectious DiseasesOfficial Publishing of INDUSEM and OPUS 12 Foundation, Inc. Users online:592  
Print this pageEmail this pageSmall font sizeDefault font sizeIncrease font size     
Home About us Editors Ahead of Print Current Issue Archives Search Instructions Subscribe Advertise Login 
 
ORIGINAL ARTICLE
Year : 2022  |  Volume : 14  |  Issue : 1  |  Page : 3-9

Effectiveness of “Resuscitation Cover All” in minimizing COVID-19 transmission to health-care workers during cardiopulmonary resuscitation


1 Department of Emergency Medicine, Mahatma Gandhi Medical College and Research Institute, Puducherry, India
2 Department of Emergency Medicine and Trauma, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India

Correspondence Address:
Dr. S Manu Ayyan
Department of Emergency Medicine and Trauma, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry - 605 006
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jgid.jgid_182_21

Rights and Permissions

Introduction: Coronavirus disease 2019 (COVID-19) is a highly contagious disease transmitted by contact, droplets, and aerosols. Front line health-care workers (HCWs), particularly emergency physicians and acute care providers, are vulnerable to being exposed while treating their sick patients. Despite appropriate personal protective equipment use, HCW gets infected, suggesting the need for multiple layers of protection such as barrier devices. Methods: We aimed to determine the effectiveness of our novel “Resuscitation Cover All”(RCA) in reducing the exposure of HCW to simulated respiratory particles and its feasibility during cardio pulmonary resuscitation (CPR). This was a pilot simulation-based study. Five CPR simulation sessions were performed in Standard and RCA protocols, individually. Exposures through contact, droplets, and aerosols were simulated using a standardized volume of liquid detergent. Under Wood's lamp illumination, exposures of participants were compared between the protocols. Rate and depth of chest compressions, time taken to intubate, interruptions in CPR, and first-pass success were analyzed. Results: Overall mean exposure in standard protocol was 4950.4 ± 1461.6 (95%confidence interval [CI]:3135.7–6765.2) sq.pixels and RCA protocol was 2203.6 ± 1499.0 (95%CI: 342.4–4064.9) sq.pixels (P = 0.019). In standard, chest compressor had the highest exposure of 3066.6 ± 1419.2 (95%CI: 2051.3–4081.9) sq.pixels followed by defibrillator assistant 1166.4 ± 767.4 (95%CI: 617.4–1715.4) sq.pixels. Chest compressor of RCA had reduced exposure compared to that of standard (P < 0.001). Hands were the most frequently exposed body part. Airway manager of RCA had no exposure over head and neck in any session. No significant difference in CPR performance metrics was observed. Conclusion: This pilot simulation-based study shows that the novel RCA device could minimize the exposure of HCW to simulated respiratory particles during CPR. Also, it might not alter the high-quality CPR performance metrics. We need more real-life evidence.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed4560    
    Printed76    
    Emailed0    
    PDF Downloaded650    
    Comments [Add]    

Recommend this journal

 

Sitemap | What's New | Feedback | Copyright and Disclaimer | Privacy Notice | Contact Us
2008 Journal of Global Infectious Diseases | Published by Wolters Kluwer - Medknow
Online since 10th December, 2008